Additional information
VEIKK , A50 , DRAWING , TABLET , 10 | {attribute:VEIKK , A50 , DRAWING , TABLET , 10 |
---|
$ 143
PROLINK Enerhome Ups 2kva Line Interactive With AVR | PRO2000
Technical Specs |
|||||||||||||||||||||||||||||
GENERAL
INPUT
OUTPUT
BATTERY
ALARM & INDICATORS
Rear Panel
|
VEIKK , A50 , DRAWING , TABLET , 10 | {attribute:VEIKK , A50 , DRAWING , TABLET , 10 |
---|
Smart UPS On-Line SRV 6000VA / 6KVA
Specification |
Single Phase In & Out | |
Rated output capacity |
6KVA/4.8KW | |
Rated |
Rated voltage |
220VAC |
AC input |
Input voltage range |
120-275VAC±5 |
Inputfrequency range |
(45-55)±0.5Hz | |
bypass voltage |
80VACx(1±5%)-285VACx(1±5%) | |
Battery Input |
battery group voltage |
192V |
battery method |
Internal | |
Battery capacity & quantity |
12V 7ah X16 PCS | |
backup time(half/full) |
half load≥10 minutes,full load≥5minutes(standard) | |
maximum input current when power on |
<150% of rated current | |
batterychargingtime |
5hours can charge to 90%(standard) | |
AC output |
Outputvoltage |
220VAC±1%(invert output) |
Output frequency |
50±5Hz(when AC input is normal) 50Hz±1% (when ac inout is abnormal ) | |
wave form |
sine wave THD<3%( linear load) sine waveTHD<8%(Nonlinear load) | |
output power factor |
0.8 | |
Overload Protection |
105-125% ,Transfer to Bypass after 1 Min | |
Output current peak coefficient |
03:01 | |
Transfer time between AC and Battery |
0ms | |
Communication and monitoring functions |
RS232(can transfer to 485,Dry node,Smart slot(can expand to SNMP,SMS and other monitoring methods) | |
Tower |
N.W(KG) |
57 |
G.W(KG) |
64 | |
Unit Size(W X H X D)mm |
515*250*620 | |
Carton Size(W X H X D)mm |
660*365*730 |
Model | STE2000 | ||||
Capacity | 2000VA/700W | ||||
INPUT | |||||
Voltage | 110/120 VAC or 220/230/240 VAC | ||||
Voltage Range | 81-145VAC or 162-290VAC | ||||
Frequency Range | 60/50 Hz (Auto sensing) | ||||
OUTPUT Voltage | 110/120 VAC or 220/230/240 VAC | ||||
AC Voltage Ragulation (Bat Mode) | ±10% | ||||
Frequency Range (Bat Mode) | 60Hz or 50Hz ± 1Hz | ||||
Transfer time | Typical 2-6ms | ||||
Waveform (Bat Mode) | Simulated Sinewave | ||||
Battery | |||||
Battery Type&Number | 12V 9Ah*2 | ||||
Charging ability | 4-6 hours recover to 90% capacity | ||||
Protection | |||||
Full protection | Overload, discharge and overcharge protection | ||||
INDICATIONS | |||||
LCD Display | AC/Battery Mode, Load/Battery Level, Input /Output Voltage ,Overload, Fault, and low Battery | ||||
LED Display | AC Mode | Green lighting | The right green LED lighting& the 2nd to 5th green LEDs gradually lighting indicating load level | ||
Battery Mode | Yellow flashing | The right green LED flashing& the 2nd to 5th green gradually lighting indicating battery capacity | |||
Fault | Red lighting | ||||
Battery mode | Sounding every 10 seconds | ||||
Low battery | Sounding every second | ||||
Overload | Sounding every 0.5 seconds | ||||
Battery Replacement Alarm | Sounding every 2 seconds | ||||
Fault | Continuously sounding | ||||
Dimension, D*W*H(mm) | 370*135*165 | ||||
Net Weight (kgs) | 11.5 | ||||
Environment | |||||
Humidity | 0-90% Relative Humidity 0-40 ℃ (Non-condensing) | ||||
Noisy Level | Less than 40dB |
MODEL |
NCTS-NU3K6 |
||||||
|
|||||||
● Load power factor is 0.8, adaptive for the development trend for electrical Equipment and the load capacity is more strong Active input power factor correction (PFC), input power factor is over 0.98 Wide input voltage and frequency range, adaptive for extreme adverse grid environment of remote areas It can be connected with generators Zero transfer time effective ensures the safety and reliability of load operation |
|||||||
Specification |
Single Phase In & Out |
||||||
Rated output capacity |
3KVA/2.4KW |
||||||
Rated |
Rated voltage |
220VAC |
|||||
AC input |
Input voltage range |
115-300VAC±5 |
|||||
Input frequency range |
(45-55)±0.5Hz |
||||||
bypass voltage |
80VACx(1±5%)-285VACx(1±5%) |
||||||
Battery Input |
battery group voltage |
72V |
|||||
battery method |
Internal |
Capacity | 650VA |
Dimension (mm) | 286 x 96 x 138 (D x W x H) |
Weight (kg) | 4.3 |
Voltage Range | 162 ~ 290VAC (Single boost) 140 ~ 300VAC (Double boost) |
Frequency | 50Hz/60Hz (Auto-sensing) |
Phase | Single + GND |
Voltage Range | 220-240VAC |
Battery Mode | 220-240VAC |
Frequency | 50Hz ±1% (Battery mode) |
Waveform | Simulated sine wave (Battery mode) Sine wave (AC mode) |
Transfer Time | 2ms typical |
Type | 12V/8.2AH x 1 |
Backup Time | 8 - 20 mins depending on load |
Recharge Time | 2-4 hours recover to 90% capacity |
Interface | RS232, USB port, RJ45/RJ11 (Optional) |
Display | LED/LCD Optional |
Alarm | Batt. Mode, low battery, overload, fault, etc. |
Short Circuit Protection | Yes (Line mode & battery mode) |
Surge Protection | Yes |
Alarm | Audible & Visual |
Overload Protection | Line mode : 100 - 120% 1 min change to fault mode >120% change to fault mode immediatelyBattery mode : 100 - 120% 1 min change to fault mode >120% change to fault mode immediately |
Intelligent Battery | Prevent overcharging of battery |
Management | Protect battery and prolong battery life |
1. AC Mode Indicator Green LED Lighting 2. Battery Mode Indicator Battery Normal : Yellow LED Lighting and Blinking every 30s Battery Low : Yellow LED Lighting and Blinking every 2s 3. Overload and Fault Indicator Overload : Red LED Blinking every 2s Fault : Red LED Lighting 4. Power Switch 5. Power AC Input 6. Backup Outlets |